73
15/02/2011 - 300014279-001-J DTG(E)130 - 35/45/65/90/115 Eco.NOxPlus
15. Maintenance
Operational mode
When the boiler is fouled, carry out the following maintenance
operations:
- Open the heating body,
- Clean the burner,
- Clean the heat exchanger using the tool provided,
- Clean the fan,
- Clean the siphon,
- Close the heating body,
- Measure the combustion.
Opening and closing the heating body
` Remove the front panel of the casing.
` Disconnect the following electrical connections:
- Ionization probe + Earth cable
,
- Fan
,
- Gas block
.
` Unscrew the gas valve joint .
` Take out the air inlet silencer .
` Unscrew the 13 holding nuts on the inspection hatch .
There is a 230 V electricity supply at the back of the fan
which must be disconnected (Marker )
.
If the inspection hatch seal remains stuck, it is necessary
to replace it
.
` Remove the inspection hatch, fan, burner and gas block unit.
- Tilt the top of the unit until the burner comes out completely,
- Then remove the inspection hatch, the fan and the gas valve unit.
` Carry out the cleaning operation.
` Connect the rear connector before putting the hatch back in
place.
` Close the heating body following the above procedure in
reverse order.
Cleaning the burner
` Remove the 3 screws and the 3 holding lugs on the burner .
` Remove the burner.
` Carry out a visual check on the general appearance of the
burner.
` Carefully clean the burner with compressed air.
` Put the burner and its fastenings back in place.
2
3
4
5
1
C000680
6
7
Vista de página 72