18
DTG(E)130 - 35/45/65/90/115 Eco.NOxPlus 15/02/2011 - 300014279-001-J
3. Description
R = Thread
Rp = Tapped connection
G = Exterior cylindrical threading, sealed by sheet gasket
(1) Basic dimension 21 mm. adjustment possible: 21 to 40 mm
(2) Basic dimension 21 mm. adjustment possible: 21 to 40 mm
DTGE130- 35 DTG130- 35 / 45 / 65 / 90 / 115
1 Heating flow G 1 R 1 1/4
2 Flow to the exchanger on the independent DHW tank (plugged as
standard) (Option) - Package HE25 or Package EA124
G1 -
6 Heating return G 1 R 1 1/4
8 Automatic air vent - -
9 Gas inlet R 3/4 R 3/4
10 Domestic hot water outlet R 3/4 R 3/4
11 Circulation R 3/4 R 3/4
12 Domestic cold water inlet R 3/4 R 3/4
13 Heat exchanger inlet - -
14 Heat exchanger outlet - -
15 Draining - -
DTGE130-35 DTG130-35 / 45 / 65 DTG130-90 / 115 DTG...130-... + BC/BP150 DTG...130-... + BC/BP200 DTG...130-... + BC/BP300
A 1100 mm 1100 mm 1322 mm - - -
G - - - 978 mm 1217 mm 1757 mm
H - - - 661 mm 796 mm 996 mm
J - - - 521 mm 651 mm 626 mm
Vista de página 17