DTG(E)130 - 35/45/65/90/115 Eco.NOxPlus 15/02/2011 - 300014279-001-J
3. Description
• DTG130-35 / 45 / 65 / 90 / 115 Eco.NOxPlus
R = Thread
G = Exterior cylindrical threading, sealed by sheet gasket
(1) Basic dimension 21 mm.
adjustment possible: 21 to 40 mm
A
21
C
460
198420
600
663
770
B
173
208
E
9
C001272
158
170
118
D
7
8
1
6
ØF
DTG130- 35 / 45 / 65 / 90 / 115
1 Heating flow G 1
2 Flow to the exchanger on the independent DHW tank (plugged as
standard) (Option) - Package HE25 or Package EA124
G1
6 Heating return G 1
7 Condensates discharge Ø 25 mm external
8 Automatic air vent -
9 Gas inlet R 3/4
A
DTG130- 35 / 45 / 65 1100 mm
DTG130-90, DTG130-115 1322 mm
B
DTG130- 35 / 45 / 65 410 mm
DTG130-90, DTG130-115 632 mm
C
DTG130- 35 / 45 / 65 124 mm
DTG130-90, DTG130-115 346 mm
D
DTG130- 35 / 45 / 65 968 mm
DTG130-90, DTG130-115 1190 mm
E
DTG130- 35 / 45 / 65 152 mm
DTG130-90, DTG130-115 374 mm
ØF
Forced flue connection:
DTG130- 35 / 45 / 65 Ø 80/125 mm
Forced flue connection:
DTG130-90, DTG130-115 Ø 100/150 mm